- LED Lighting
- Optoelectronic
- Sensors
- Power Supply
- Electromechanics
- Signal Technology
- Memory & Storage
- Thermal Management
- Circuit Breaker
- Hi-Rel
- Diverse
|
||
Manufacturer: | Laird Thermal Systems | |
Productgroup: | Liquid Cooling Systems | |
Part Number: | NRC400-T0-00-PC2 | |
Series: | Nextreme | |
Datasheet: | Open datasheet | |
State: | 🟢 Active |
Note article Request article |
Qc Max : | 400 W | ||
Flow Rate: | 1 L/min @ 1.05 bar | ||
Supply Voltage : | 115 | 230 V | ||
Pump: | Centrifugal | ||
Heat transfer type : | Liquid-To-Air | ||
Heat transfer cold side: | Convection | ||
Heat transfer hot side: | Convection | ||
Length: | 413 mm | ||
Width: | 274 mm | ||
Heigth: | 400 mm | ||
Min. operating temperature: | 10 °C | ||
Max. operating temperature: | 40 °C |
|
Hint: current revision of the supplier datasheet is applicable