5%%A
Telefonnummer  +49 9135 73666 65
Merkliste Klammer auf0Klammer zu
Deutsche Sprache
Mobile Menu
Mobile Menu
Articles added
5%%E
6%%A
6%%E

F-DG-Series from DIGISOUND


With the F-DG series, DIGISOUND offers a variety of Transducer in different designs. Please contact us if a component is not listed or if you are looking for an alternative or need a customized solution.
Filter  (11/11 Product)
Sorting
View
3%%A
3%%E
  • Manufacturer
  • Type
  • Operating Voltage [Vdc]
       -   

  • Current consumption [mA]
       -   

  • Resonant Frequency [Hz]
       -   

  • SPL [dB/10cm]
       -   

  • Terminal
  • Dimensions [mm]
  • Weight [g]
       -   

  • Min. operating temperature [°C]
       -   

  • Max. operating temperature [°C]
       -   

2%%A
2%%E
Reset all filters [x]
Sorting
DIGISOUND
Transducer | Magnetisch | 3-12 V
Datasheet:F/DG-06P PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 3-12 Vdc
Current consumption: 50 mA
Resonant Frequency: 2048 Hz
SPL: 90 dB/10cm
Terminal: PIN
Dimensions: Ø16 mm
Weight: 4,6 g
Min. operating temperature: -20 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 3-8 V
Datasheet:F/DG-06PS/L PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 3-8 Vdc
Current consumption: 50 mA
Resonant Frequency: 2048 Hz
SPL: 90 dB/10cm
Terminal: PIN
Dimensions: Ø16 mm
Weight: 7 g
Min. operating temperature: -20 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 1-2 V
Datasheet:F/DG-105P PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 1-2 Vdc
Current consumption: 10 mA
Resonant Frequency: 2048 Hz
SPL: 70 dB/10cm
Terminal: PIN
Dimensions: Ø 12 mm
Weight: 2 g
Min. operating temperature: -20 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 1-2 V
Datasheet:F/DG-111GP PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 1-2 Vdc
Current consumption: 20 mA
Resonant Frequency: 2048 Hz
SPL: 80 dB/10cm
Terminal: PIN
Dimensions: Ø 12 mm
Weight: 1,5 g
Min. operating temperature: -20 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 1-2 V
Datasheet:F/DG-111P PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 1-2 Vdc
Current consumption: 20 mA
Resonant Frequency: 2048 Hz
SPL: 80 dB/10cm
Terminal: PIN
Dimensions: Ø 12 mm
Weight: 1,5 g
Min. operating temperature: -20 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 1-2 V
Datasheet:F/DG-111P LF PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 1-2 Vdc
Current consumption: 20 mA
Resonant Frequency: 2048 Hz
SPL: 80 dB/10cm
Terminal: PIN
Dimensions: Ø 12 mm
Weight: 1,5 g
Min. operating temperature: -20 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 3-8 V
Datasheet:F/DG-111PC5V PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 3-8 Vdc
Current consumption: 50 mA
Resonant Frequency: 2048 Hz
SPL: 88 dB/10cm
Terminal: PIN
Dimensions: Ø 12 mm
Weight: 1,5 g
Min. operating temperature: -20 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Mechanisch | 6-18 V
Datasheet:F/DG-12P PDF
Manufacturer DIGISOUND
Type: Mechanisch
Operating Voltage: 6-18 Vdc
Current consumption: 40 mA
Resonant Frequency: 2048 Hz
SPL: 95 dB/10cm
Terminal: -
Dimensions: Ø16 mm
Weight: 7 g
Min. operating temperature: -30 °C
Max. operating temperature: 100 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 6-18 V
Datasheet:F/DG-12PS/L PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 6-18 Vdc
Current consumption: 40 mA
Resonant Frequency: 2048 Hz
SPL: 95 dB/10cm
Terminal: -
Dimensions: Ø16 mm
Weight: 7 g
Min. operating temperature: -30 °C
Max. operating temperature: 100 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 4-7 V
Datasheet:F/DGX-05P PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 4-7 Vdc
Current consumption: 50 mA
Resonant Frequency: 2400 Hz
SPL: 90 dB/10cm
Terminal: PIN
Dimensions: 2400 mm
Weight: 2 g
Min. operating temperature: -40 °C
Max. operating temperature: 70 °C
Models: -
DIGISOUND
Transducer | Magnetisch | 8-15 V
Datasheet:F/DGX-12P PDF
Manufacturer DIGISOUND
Type: Magnetisch
Operating Voltage: 8-15 Vdc
Current consumption: 40 mA
Resonant Frequency: 2400 Hz
SPL: 85 dB/10cm
Terminal: -
Dimensions: 2400 mm
Weight: 2 g
Min. operating temperature: -40 °C
Max. operating temperature: 85 °C
Models: -
Hint: current revision of the supplier datasheet is applicable

Design-In Support

Do you have questions about the F-DG-Series from DIGISOUND or are you looking for alternatives? As an authorized distributor, we maintain a very close exchange with DIGISOUND and are happy to advise you with our many years of experience in the selection of suitable components and possible adaptations. Please contact us!
Support

Brochures, flyers and presentations

2%%A
2%%E
1%%A
1%%E
1%%A
1%%E
4%%A
4%%E
7%%A
7%%E